更新 BMC#
创建一个
update_bmc.json
文件,内容如下{ "Targets" :["/redfish/v1/UpdateService/FirmwareInventory/HostBMC_0"] }
更新固件
nvfwupd -t ip=<bmc-ip-address> user=<bmc-username> password=<bmc-password> update_fw \ -p nvfw_DGX_250212.1.1.fwpkg -y -s update_bmc.json
示例输出
FW recipe: ['nvfw_DGX_250212.1.1.fwpkg'] {"@odata.type": "#UpdateService.v1_6_0.UpdateService", "Messages": [{"@odata.type": "#Message.v1_0_8.Message", "Message": "A new task /redfish/v1/TaskService/Tasks/2 was created.", "MessageArgs": ["/redfish/v1/TaskService/Tasks/2"], "MessageId": "Task.1.0.New", "Resolution": "None", "Severity": "OK"}, {"@odata.type": "#Message.v1_0_8.Message", "Message": "The action UpdateService.MultipartPush was submitted to do firmware update.", "MessageArgs": ["UpdateService.MultipartPush"], "MessageId": "UpdateService.1.0.StartFirmwareUpdate", "Resolution": "None", "Severity": "OK"}]} FW update started, Task Id: 2 Wait for FirmwareUpdateStarted in MessageId Wait for FirmwareUpdateStarted in MessageId Wait for FirmwareUpdateStarted in MessageId Wait for FirmwareUpdateStarted in MessageId Wait for FirmwareUpdateStarted in MessageId Wait for FirmwareUpdateStarted in MessageId Wait for FirmwareUpdateStarted in MessageId Wait for FirmwareUpdateStarted in MessageId Wait for FirmwareUpdateStarted in MessageId Wait for FirmwareUpdateStarted in MessageId PercentageComplete: 6 TaskState: Running PercentComplete: 6 TaskStatus: OK ... PercentageComplete: 100 TaskState: Completed PercentComplete: 100 TaskStatus: OK Firmware update successful! Overall Time Taken: 0:36:11 Refer to 'DGX B200 Firmware Update Document' on activation steps for new firmware to take effect.
重置 BMC,以便 BMC 启动新固件
$ ipmitool mc reset cold # Wait a couple of minutes and confirm the BMC is back online. $ ipmitool mc info
重启系统。